Diagnosis Procedure
- CHECK DAYTIME RUNNING LIGHT RELAY FUSE
Check that the following fuse is not fusing.
FUSE REFERENCE CHARTUnit Location Fuse No. Capacity Daytime running light relay IPDM E/R #59 10 A Is the fuse fusing?
YES: Replace the fuse after repairing the applicable circuit.
NO: GO TO 2.
- CHECK DAYTIME RUNNING LIGHT RELAY POWER SUPPLY
- Remove the daytime running light relay.
- Check voltage between the daytime running light relay harness connector and the ground.VOLTAGE REFERENCE CHART
Terminals Voltage (Approx.) (+) (-) Daytime running light relay Ground Connector Terminal E53 1 Battery voltage 3 Is the measurement value normal?
YES: GO TO 3.
NO: Repair harnesses or connectors.
- CHECK DAYTIME RUNNING LIGHT RELAY
Check the daytime running light relay. Refer to "COMPONENT INSPECTION ".
Is the daytime running light relay normal?
YES: GO TO 4.
NO: Replace daytime running light relay.
- CHECK DAYTIME RUNNING LIGHT RELAY CONTROL SIGNAL OUTPUT
CONSULT-III ACTIVE TEST
- Turn the ignition switch OFF.
- Install the daytime running light relay.
- Turn the ignition switch ON.
- Select "EXTERNAL LAMPS" of IPDM E/R active test item.
- With operating the test item, check voltage between the IPDM E/R harness connector and the ground.VOLTAGE REFERENCE CHART
Terminals Test item Voltage (Approx.) (+) (-) IPDM E/R Ground EXTERNAL LAMPS Connector Terminal E9 105 TAIL 0 V Off Battery voltage Is the measurement value normal?
YES: Check the parking lamp circuit. Refer to "DIAGNOSIS PROCEDURE ".
Fixed at 0 V: GO TO 5.
Fixed at battery voltage: Replace IPDM E/R.
- CHECK DAYTIME RUNNING LIGHT RELAY CONTROL SIGNAL OPEN CIRCUIT
- Remove the daytime running light relay.
- Disconnect IPDM E/R harness connector.
- Check continuity between the IPDM E/R harness connector and the daytime running light relay harness connector.CONTINUITY REFERENCE CHART
IPDM E/R Daytime running light relay Continuity Connector Terminal Connector Terminal E9 105 E53 2 Existed Does continuity exist?
YES: GO TO 6.
NO: Repair the harnesses or connectors.
- CHECK DAYTIME RUNNING LIGHT RELAY CONTROL SIGNAL SHORT CIRCUIT
Check continuity between the IPDM E/R harness connector and the ground.
CONTINUITY REFERENCE CHARTIPDM E/R Ground Continuity Connector Terminal E9 105 Not existed Does continuity exist?
YES: Repair the harnesses or connectors.
NO: Replace IPDM E/R.