LEMON Manuals: Even more car manuals for everyone
Home >> Hummer >> 2008 >> H2 4D Utility Wagon >> Repair and Diagnosis >> External Pages >> Different car >> Section 461 (Wiring Systems And Power Management - Diagnostic Information And Procedures) >> Diagnostic Information and Procedures >> Yazaki Connectors (2-Way) >> Terminal Removal Procedure

Terminal Removal Procedure

WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2012 GMC Yukon XL, 2012 GMC Yukon, 2012 Chevrolet Tahoe, 2012 Chevrolet Suburban, and 2012 Chevrolet Avalanche. However, it is still accessible from the selected car via links, so may be relevant.
  1. Disconnect the connector from the component.
  2. Fig 1: Identifying Terminal Position Assurance (Yakazi)
    GM1454532Courtesy of GENERAL MOTORS COMPANY
  3. Insert a small flat-blade tool in the slot below the front loaded terminal position assurance (TPA) and pry up.
  4. Remove the TPA by pulling it out of the connector.
  5. Push the wire side of the terminal that is being removed toward the connector and hold it in position.
  6. Fig 2: View Of Inserting Tool Into Terminal Cavity (Yakazi)
    GM1454546Courtesy of GENERAL MOTORS COMPANY
  7. Insert the J-38125-553 on a slight upward angle into the cavity below the terminal to be removed. Ensure that the pointed on the end of the tool is facing the bottom of the terminal and it stays in contact with the terminal until it stops on the plastic terminal retainer.
  8. Fig 3: View Of Pulling Terminal Out Of Connector (Yakazi)
    GM1454553Courtesy of GENERAL MOTORS COMPANY
  9. Gently pry the plastic terminal retainer down and carefully pull the terminal out of the connector. Always remember never use force when pulling a terminal out of a connector. If the terminal is difficult to remove, repeat the entire procedure.
  10. Repair the terminal by following the Repairing Connector Terminals (Terminated Lead Repair) , Repairing Connector Terminals (Terminal Repair)  procedure.
  11. Insert the repaired terminal back into the cavity. Repeat the diagnostic procedure to verify the repair and reconnect the connector bodies.