LEMON Manuals: Even more car manuals for everyone
Home >> Hummer >> 2008 >> H2 4D Utility Wagon >> Repair and Diagnosis >> External Pages >> Different car >> Section 461 (Wiring Systems And Power Management - Diagnostic Information And Procedures) >> Diagnostic Information and Procedures >> Repairing Connector Terminals (Terminated Lead Repair)

Repairing Connector Terminals (Terminated Lead Repair)

WARNING: This page does not describe the selected car, but rather 8 other vehicles, including the 2012 GMC Yukon XL, 2012 GMC Yukon, 2012 Chevrolet Tahoe, 2012 Chevrolet Suburban, and 2012 Chevrolet Avalanche. However, it is still accessible from the selected car via links, so may be relevant.

Special Tools 

EL-38125-10  Splice Sleeve Crimp Tool

For equivalent regional tools, refer to Special Tools .

NOTE:

All repairs near the engine manifold, turbo engine and all exhaust pipes should follow the High Temperature Wiring Repairs procedures.

For high temperature wiring repairs, refer to High Temperature Wiring Repairs .

Terminated leads are terminals that are crimped onto wires. The terminated lead can be used throughout the vehicle since it is designed for temperatures up to 150°C. The length of the wire is 450 mm.

  1. Use the connector end view to identify the correct terminated lead.
  2. The terminated lead package should include a DuraSeal splice sleeve. If not, use the chart to in Splicing Copper Wire Using Splice Sleeves to identify the correct DuraSeal splice sleeve, refer to Splicing Copper Wire Using Splice Sleeves .