LEMON Manuals: Even more car manuals for everyone
Home >> Honda >> 2021 >> CR-V EX-L, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 57 (VSA System - DTC Diagnostics (1 Of 2) (Hybrid)) >> DTC Troubleshooting >> DTC P0A4B (293), P0A4C (473), P0A4D (474)

DTC P0A4B (293), P0A4C (473), P0A4D (474)

WARNING: This page is about a different variant/trim than selected.

DTC P0A4B  : Generator Motor Rotor Position Sensor Circuit

DTC P0A4C  : Generator Motor Rotor Position Sensor Circuit Range/Performance

DTC P0A4D  : Generator Motor Rotor Position Sensor Circuit Low

NOTE:  Before you troubleshoot, review the general troubleshooting information .

DTC Description Confirmed DTC Pending DTC Freeze Frame
P0A4B Generator Motor Rotor Position Sensor Circuit      
P0A4C Generator Motor Rotor Position Sensor Circuit Range/Performance      
P0A4D Generator Motor Rotor Position Sensor Circuit Low      

DTC (Electric Powertrain)

  1. Problem verification

    -1. Turn the vehicle to the ON mode.

    -2. Clear the DTC with the HDS.

    -3. Turn the vehicle to the OFF (LOCK) mode.

    -4. Turn the vehicle to the ON mode.

    -5. Monitor the OBD STATUS for DTC P0A4B, P0A4C, and P0A4D in the DTCs MENU with the HDS.

    DTC Description Confirmed DTC Pending DTC Freeze Frame
    P0A4B Generator Motor Rotor Position Sensor Circuit      
    P0A4C Generator Motor Rotor Position Sensor Circuit Range/Performance      
    DTC Description Confirmed DTC Pending DTC Freeze Frame
    P0A4D Generator Motor Rotor Position Sensor Circuit Low      

    Does the HDS indicate FAILED?

    YES 

    The failure is duplicated. Go to step 2.

    NO 

    If the HDS indicates PASSED, the system is OK at this time but has an intermittent failure. If the HDS indicates NOT COMPLETED, keep the vehicle in the ON mode until an indication comes on. If the freeze data/on-board snapshot of this DTC is recorded, try to reproduce the failure under the same conditions with the freeze data/on-board snapshot.

  2. Generator motor motor rotor position sensor circuit check

    -1. Do the generator motor motor rotor position sensor circuit inspection .

    Is it OK?

    YES 

    The generator motor motor rotor position sensor circuit is OK. Faulty generator motor motor rotor position sensor. Replace the transmission (e-CVT) assembly .

    NO 

    Repair an open or short in the generator motor motor rotor position sensor circuit between the PCU and the generator motor motor rotor position sensor.