LEMON Manuals: Even more car manuals for everyone
Home >> Honda >> 2021 >> CR-V EX-L, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 56 (Battery Management System - Advanced Diagnostics & Troubleshooting (Hybrid)) >> DTC Troubleshooting >> DTC P0562 (15) (Battery Condition Monitor Module)

DTC P0562 (15) (Battery Condition Monitor Module)

WARNING: This page is about a different variant/trim than selected.

DTC P0562  : Battery Condition Monitor Module System Voltage Low

NOTE:  Before you troubleshoot, review the general troubleshooting information .

DTC Description Confirmed DTC Pending DTC Freeze Frame
P0562 Battery Condition Monitor Module System Voltage Low      

DTC (Electric Powertrain)

  1. Fuse check

    -1. Turn the vehicle to the OFF (LOCK) mode.

    -2. Check the following fuse.

    Fuse No. E5

    Is the fuse OK?

    YES 

    Go to step 2.

    NO 

    Go to step 4.

  2. Problem verification

    -1. Turn the vehicle to the ON mode.

    -2. Clear the DTC with the HDS.

    -3. Turn the vehicle to the OFF (LOCK) mode.

    -4. Turn the vehicle to the ON mode.

    -5. Check for Pending or Confirmed DTCs with the HDS.

    DTC Description Confirmed DTC Pending DTC Freeze Frame
    P0562 Battery Condition Monitor Module System Voltage Low      

    Is DTC P0562 indicated?

    YES 

    The failure is duplicated. Go to step 3.

    NO 

    Intermittent failure, the system is OK at this time. Check for poor connections or loose terminals at the No. E5 fuse and the battery condition monitor module.

  3. Open wire check (VBU/+B_IMA1 line)

    -1. Turn the vehicle to the OFF (LOCK) mode.

    -2. Remove the service plug and the IPU cover .

    -3. Disconnect the following connector.

    Battery condition monitor module connector E (32P)

    -4. Do the 12 volt battery terminal reconnection procedure .

    -5. Measure the voltage between test points 1 and 2.

    Test condition Vehicle OFF (LOCK) mode
      Battery condition monitor module connector E (32P): disconnected
    Test point 1 Battery condition monitor module connector E (32P) No. 1
    Test point 2 Body ground

    Is there battery voltage?

    YES 

    Replace the battery condition monitor module .

    NO 

    Repair an open in the VBU/+B_IMA1 wire between the No. E5 fuse and the battery condition monitor module (E1).

  4. Shorted wire check (VBU/+B_IMA1 line)

    -1. Remove the service plug and the IPU cover .

    -2. Disconnect the following connector.

    Battery condition monitor module connector E (32P)

    -3. Measure the resistance between test points 1 and 2.

    Test condition Vehicle OFF (LOCK) mode
      Battery condition monitor module connector E (32P): disconnected
    Test point 1 Battery condition monitor module connector E (32P) No. 1
    Test point 2 Body ground

    Is there 1 MΩ or more?

    YES 

    Replace the battery condition monitor module .

    NO 

    Repair a short in the VBU/+B_IMA1 wire between the battery condition monitor module (E1) and the No. E5 fuse. Also replace the No. E5 fuse.