LEMON Manuals: Even more car manuals for everyone
Home >> Honda >> 2021 >> CR-V EX-L, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 14 (HVAC System - Diagnostics (Hybrid)) >> DTC Troubleshooting >> DTC B1232 (A-A6), B1232 (0A)

DTC B1232 (A-A6), B1232 (0A)

WARNING: This page is about a different variant/trim than selected.

DTC B1232, DTC screen A-A6, or DTC screen 0A  : A short in the evaporator temperature sensor circuit

DTC Description DTC
B1232 A short in the evaporator temperature sensor circuit  

DTC (AC)

  1. Problem verification

    -1. Clear the DTC with the HDS.

    -2. Turn the vehicle to the OFF (LOCK) mode and then the ON mode.

    -3. Do the Self-Diagnostic Function with the HDS or the climate control unit .

    -4. Check for DTCs.

    DTC Description DTC
    B1232 A short in the evaporator temperature sensor circuit  

    Is DTC B1232, Error on the DTC screen A-A6 (climate control panel without display), or DTC screen 0A (climate control panel with display) indicated?

    YES 

    The failure is duplicated. Go to step 2.

    NO 

    Intermittent failure. Check for loose wires or poor connections on the evaporator temperature sensor circuit.

  2. Shorted wire check (TEVA line)

    -1. Turn the vehicle to the OFF (LOCK) mode.

    -2. Disconnect the following connectors.

    Climate control unit connector B (24P)
    Evaporator temperature sensor 2P connector

    -3. Measure the resistance between test points 1 and 2.

    Test condition Vehicle OFF (LOCK) mode
    Climate control unit connector B (24P): disconnected
    Evaporator temperature sensor 2P connector: disconnected
    Test point 1 Climate control unit connector B (24P) No. 8
    Test point 2 Body ground

    Is there 1 MΩ or more?

    YES 

    The TEVA wire is not shorted. Go to step 3.

    NO 

    Repair a short to body ground in the TEVA wire.

  3. Shorted wire check (TEVA line to SENS-COM line)

    -1. Measure the resistance between test points 1 and 2.

    Test condition Vehicle OFF (LOCK) mode
    Climate control unit connector B (24P): disconnected
    Evaporator temperature sensor 2P connector: disconnected
    Test point 1 Climate control unit connector B (24P) No. 8
    Test point 2 Climate control unit connector B (24P) No. 10

    Is there 1 MΩ or more?

    YES 

    The TEVA wire and the SENS-COM wire are OK. Go to step 4.

    NO 

    Repair a short in the TEVA wire to the SENS-COM wire.

  4. Evaporator temperature sensor check

    -1. Test the evaporator temperature sensor .

    Is the evaporator temperature sensor OK?

    YES 

    Replace the climate control unit .

    NO 

    Replace the evaporator temperature sensor .