DTC B1245 or DTC indicator 7: A Short in the Rear Air Mix Control Motor Circuit
- Clear the DTCs with the HDS.
- Turn the ignition switch to LOCK (0) and then back to ON (II).
- Do the self-diagnostic function with the HDS (see HOW TO USE THE SELF-DIAGNOSTIC FUNCTION WITH THE HDS ) or the HVAC control unit (see HOW TO USE THE HVAC CONTROL UNIT SELF-DIAGNOSTIC FUNCTION WITHOUT THE HDS ).
- Check for DTCs.
Is DTC B1245 or 7 indicated?
YES -Go to step 5
NO -Intermittent failure.
- Check for DTCs.
Are these DTCs also present; B1234 or 2, and/or B2980 or 6?
YES -Go to step 13.
NO -Go to step 6.
- Turn the ignition switch to LOCK (0).
- Test the rear air mix control motor (see
REAR AIR MIX CONTROL MOTOR TEST
).
Is the rear air mix control motor OK?
YES -Go to step 8.
NO -Replace the rear air mix control motor (see REAR EVAPORATOR TEMPERATURE SENSOR REPLACEMENT ).
- Disconnect the rear air mix control motor 7P connector.
- Disconnect HVAC control unit connector A (24P).
- Check for continuity between HVAC control unit connector A (24P) terminal No. 15 and body ground.Fig 1: Checking Continuity Between HVAC Control Unit Connector A (24P) Terminal No. 15 And Body Ground
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there continuity?
YES -Repair a short to body ground in the wire between the HVAC control unit and the rear air mix control motor.
NO -Go to step 11.
- Check for continuity between HVAC control unit connector A (24P) terminals No. 14 and No. 15.
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there continuity?
YES -Repair a short in the wire(s).
NO -Go to step 12.
- Turn the ignition switch to ON (II), and measure the voltage between HVAC control unit connector A (24P) terminal No. 15 and body ground.Fig 3: Measuring Voltage Between HVAC Control Unit Connector A (24P) Terminal No. 15 And Body Ground
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there any voltage?
YES -Repair a short to power in the wire between the HVAC control unit and the rear air mix control motor. This short may also damage the HVAC control unit. Repair a short to power before replacing the HVAC control unit.
NO -Substitute a known-good HVAC control unit, and recheck. If the symptom/indication goes away, replace the original HVAC control unit (see HVAC CONTROL UNIT REMOVAL/INSTALLATION ).
- Turn the ignition switch to LOCK (0), and disconnect HVAC control unit connector A (24P).
- Disconnect these items:
- Front air mix control motor
- Rear air mix control motor
- A/C pressure sensor
- Check for continuity between HVAC control unit connector A (24P) terminal No. 14 and body ground.Fig 4: Checking Continuity Between HVAC Control Unit Connector A (24P) Terminal No. 14 And Body Ground
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there continuity?
YES -Repair a short to body ground in the wire.
NO -Go to step 16.
- Turn the ignition switch to ON (II), and check the same terminal for voltage to body ground.
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there any voltage?
YES -Repair a short to power in the wire. This short may have also damaged the HVAC control unit. Repair a short to power before replacing the HVAC control unit.
NO -Go to step 17.
- Turn the ignition switch to LOCK (0).
- Reconnect the HVAC control unit connector A (24P).
- Turn the ignition switch to ON (II), and measure the voltage between HVAC control unit connector A (24P) terminal No. 14 and body ground.Fig 6: Measuring Voltage Between HVAC Control Unit Connector A (24P) Terminal No. 14 And Body Ground
Courtesy of AMERICAN HONDA MOTOR CO., INC.
Is there about 5 V?
YES -Go to step 20
NO -Check for a loose wire or poor connection at HVAC control unit connector A (24P). If the connection is good, substitute a known-good HVAC control unit and recheck. If the symptom/indication goes away, replace the original HVAC control unit (see HVAC CONTROL UNIT REMOVAL/INSTALLATION ).
- While checking the same terminal for voltage to ground, reconnect these items individually and note the voltage reading each time:
- Front air mix control motor
- Rear air mix control motor
- A/C pressure sensor
Does the voltage remain at about 5 V?
YES -Substitute a known-good HVAC control unit and recheck. If the symptom/indication goes away, replace the original HVAC control unit (see HVAC CONTROL UNIT REMOVAL/INSTALLATION ).
NO -Replace the component that caused the voltage drop.