LEMON Manuals: Even more car manuals for everyone
Home >> GMC >> 2018 >> Acadia Denali, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 166 (Engine Controls And Fuel - 3.6L (LGX LF4) - Repair Instructions) >> Repair Instructions >> Air Cleaner Outlet Rear Duct Replacement (LF4) >> Installation Procedure

Installation Procedure

WARNING: This page is about a different car, the 2017 Cadillac ATS. However, it is still accessible from the selected car via links, so may be relevant.
    Fig 1: Air Cleaner Outlet Rear Duct, Clamp And Retainer Spring
    GM4176638Courtesy of GENERAL MOTORS COMPANY
  1. Install Air Cleaner Outlet Rear Duct (3)
  2. Connect the electrical connector.
  3. Engage Retainer Spring (2) @ Air Cleaner Outlet Rear Duct (3)
  4. CAUTION:

    Refer to Fastener Caution .

    NOTE:

    Ensure the outlet duct is fully seated to the mating surfaces before clamping. Verify that the cuff is not rolled under.

  5. Install Air Cleaner Outlet Rear Duct Clamp (1) @ Air Cleaner Outlet Front Duct 4 N.m (35 lb in)
  6. Fig 2: Positive Crankcase Ventilation Tube, Air Cleaner Outlet Rear Duct And Clamp
    GM4176545Courtesy of GENERAL MOTORS COMPANY
  7. Install Positive Crankcase Ventilation Tube (2) @ Air Cleaner Outlet Rear Duct (3)
  8. Install Air Cleaner Outlet Rear Duct Clamp (1) @ Positive Crankcase Ventilation Tube (2) 4 N.m (35 lb in)
  9. Fig 3: Charge Air Bypass Valve Hose, Air Cleaner Outlet Rear Duct And Clamp
    GM4176479Courtesy of GENERAL MOTORS COMPANY
  10. Install Charge Air Bypass Valve Hose (2) @ Air Cleaner Outlet Rear Duct (3)
  11. Install Charge Air Bypass Valve Hose Clamp (1) @ Charge Air Bypass Valve Hose (2) 4 N.m (35 lb in)
  12. Install Intake Manifold Cover. Refer to Intake Manifold Cover Replacement (LF4)