Turn Signal Lamps and/or Indicators Inoperative
Turn Signal Lamps and/or Indicators Inoperative
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
| Schematic Reference: Exterior Lights Schematics Connector End View Reference: Lighting Systems Connector End Views or Instrument Panel, Gages, and Console Connector End Views in Instrument Panel, Gages, and Console |
||||
| 1 | Did you review the Exterior Lighting Systems Description and Operation and perform the necessary inspections? | - | Go to Step 2 | Go to Exterior Lighting Systems Description and Operation |
| 2 | Verify that the turn signal lamps and/or indicators are inoperative. Do the turn signal lamps and/or indicators operate normally? |
- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
| 3 | Are only the turn signal indicators in the instrument panel cluster (IPC) inoperative? | - | Go to Step 4 | Go to Step 6 |
| 4 | Test the inoperative front turn signal switch signal circuit to the IPC for an open or high resistance. Refer to Circuit Testing
in Wiring Systems. Did you find a problem? |
- | Go to Step 14 | Go to Step 5 |
| 5 |
|
- | Go to Step 23 | - |
| 6 | Is only one turn signal lamp inoperative? | - | Go to Step 7 | Go to Step 8 |
| 7 | Inspect the inoperative bulb/socket for an internal short, poor terminal contact, or an open filament. Did you find a problem? |
- | Go to Step 19 | Go to Step 15 |
| 8 | Inspect the TURN fuse in the IP fuse block. Is the fuse open? |
- | Go to Step 13 | Go to Step 9 |
| 9 |
|
- | Go to Step 16 | Go to Step 10 |
| 10 |
|
B+ | Go to Step 11 | Go to Step 20 |
| 11 | Test for an open or high resistance in the following circuits, and refer to Circuit Testing
in Wiring Systems:
Did you find a problem? |
- | Go to Step 17 | Go to Step 12 |
| 12 |
|
- | Go to Step 21 | Go to Step 20 |
| 13 | Test the following circuits for a short to ground. Refer to Circuit Testing
in Wiring Systems:
Did you find a problem? |
- | Go to Step 18 | Go to Step 21 |
| 14 | Repair the open or high resistance in the inoperative front turn signal switch signal circuit to the IPC. Refer to Wiring Repairs
in Wiring Systems. Did you complete the repair? |
- | Go to Step 22 | - |
| 15 | Repair the following conditions, and refer to Wiring Repairs
in Wiring Systems:
Did you complete the repair? |
- | Go to Step 22 | - |
| 16 | Repair the open or high resistance in the ignition 1 voltage circuit. Refer to Wiring Repairs
in Wiring Systems. Did you complete the repair? |
- | Go to Step 22 | - |
| 17 | Repair the open or high resistance in one of the following circuits, and refer to Wiring Repairs
in Wiring Systems:
Did you complete the repair? |
- | Go to Step 22 | - |
| 18 | Repair the short to ground found in one of the following circuits, and refer to Wiring Repairs
in Wiring Systems:
Did you complete the repair? |
- | Go to Step 22 | - |
| 19 | Replace or repair the inoperative bulb/socket. Did you complete the repair? |
- | Go to Step 22 | - |
| 20 | Replace the multifunction turn signal switch. Refer to Multifunction, Turn Signal Switch Replacement
in Steering Wheel and Column. Did you complete the repair? |
- | Go to Step 22 | - |
| 21 | Replace the turn signal lamp flasher. Refer to Hazard and Turn Signal Flasher Replacement . Did you complete the repair? |
- | Go to Step 22 | - |
| 22 | Operate the system in order to verify the repair. Did you correct the condition? |
- | System OK | Go to Step 3 |