Air Conditioning (A/C) Diagnostics - Pressure Zone C
WARNING: This page is about a different car, the 2007 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
Air Conditioning (A/C) Diagnostics - Pressure Zone C
| Step | Action | Yes | No |
|---|---|---|---|
DEFINITION: The low and the high side pressures are both higher than normal.
|
|||
| 1 | Were you sent here from the air conditioning (A/C) System Performance Test? | Go to Step 2 | Go to Air Conditioning (A/C) System Performance Test (L61) or Air Conditioning (A/C) System Performance Test (L66 Red Line) or Air Conditioning (A/C) System Performance Test (L66 Base) or Air Conditioning (A/C) System Performance Test (LAT) |
| 2 |
|
Go to Step 3 | Go to Step 5 |
| 3 | Visually inspect for the following conditions:
Do any of these conditions exist? |
Go to Step 4 | Go to Step 6 |
| 4 | Repair the air flow restriction. Is the action complete? |
Go to Step 9 | - |
| 5 | Repair the fault to the cooling fan operation. Refer to Cooling Fan Inoperative (2.2L and 2.4L)
or Cooling Fan Inoperative (3.5L)
. Is the repair complete? |
Go to Step 9 | - |
| 6 |
CAUTION:
Refer to Moving Parts and Hot Surfaces Caution
. Feel the liquid line on both sides of the thermal expansion valve (TXV).Are the temperatures on both sides of the TXV similar? |
Go to Step 7 | Go to Step 8 |
| 7 | Replace the damaged or faulty TXV. Refer to Thermal Expansion Valve Replacement (L61/LAT) or Thermal Expansion Valve Replacement (L66) . Is the action complete? |
Go to Step 9 | - |
| 8 |
|
Go to Step 9 | - |
| 9 |
|
Go to Step 10 | Go to Air Conditioning (A/C) System Performance Test (L61) or Air Conditioning (A/C) System Performance Test (L66 Red Line) or Air Conditioning (A/C) System Performance Test (L66 Base) or Air Conditioning (A/C) System Performance Test (LAT) |
| 10 | Operate the system in order to verify the repair. Did you find and correct the condition? |
System OK | Go to Symptoms - HVAC Systems - Manual |