Pinpoint Test A : The AUTOLAMPS Are Inoperative
WARNING: This page is about a different car, the 2019 Ford F-550 Super Duty, 2019 Ford F-450 Super Duty, 2019 Ford F-350 Super Duty, and 2019 Ford F-250 Super Duty. However, it is still accessible from the selected car via links, so may be relevant.
The Autolamps Are Inoperative
Refer to Headlamps/Autolamps for schematic and connector information.
Normal Operation and Fault Conditions
REFER to: Exterior Lighting - Overview .
REFER to: Exterior Lighting - System Operation and Component Description .
Possible Sources
- Headlamp concern
- Light sensor
- BCM
- A1 CHECK THE MANUAL HEADLAMP OPERATION
- Place the headlamp switch in the HEADLAMPS and then OFF positions.
Do the headlamps operate correctly?
Yes GO to A2 No REFER to: Headlamps . - A2 CHECK FOR VOLTAGE TO THE LIGHT SENSOR
- Ignition OFF.
- Disconnect: Autolamp Sensor C287 (vehicles with EMTC).
- Disconnect: Autolamp/Sunload Sensor C286 (vehicles with DATC).
- Ignition ON.
- Place the headlamp switch in the AUTOLAMPS position.
- Measure:
Vehicles With EMTC
Positive Lead Measurement / Action Negative Lead C287-2 Ground Vehicles With DATC
Positive Lead Measurement / Action Negative Lead C286-2 Ground
Is the voltage approximately 5 volts?
Yes INSTALL a new autolamp or autolamp/sunload sensor. REFER to: Light Sensor . No GO to A3 - A3 CHECK FOR CORRECT BCM (BODY CONTROL MODULE) OPERATION
- Disconnect and inspect all BCM connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect the BCM connectors. Make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. Refer to BCM Guided Routine . No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.