Pinpoint Test D: A Single Power Window Is Inoperative - LH (Left-Hand) Front
- Refer to POWER WINDOWS
for schematic and connector information.
Normal Operation and Fault Conditions
Possible Sources
- Wiring, terminals or connectors
- Master window control switch
- LH front window regulator motor
- D1 CHECK THE POWER WINDOW UPWARD AND/OR DOWNWARD OPERATION
- Ignition OFF.
- Disconnect: Master Window Control Switch C504B.
- Ignition ON.
- To check downward window operation, connect fused jumper wires:
Positive Lead Measurement / Action Negative Lead C504B-6 C504B-4 C504B-3 C504B-2
- To check upward window operation, connect fused jumper wires:
Positive Lead Measurement / Action Negative Lead C504B-6 C504B-3 C504B-4 C504B-2
Does the LH front window move up and/or down?
Yes REMOVE the jumper wires. INSTALL a new master window control switch. REFER to: Front Door Window Control Switch . No REMOVE the jumper wires. GO to D2 - D2 CHECK THE POWER WINDOW CIRCUITS FOR AN OPEN
- Ignition OFF.
- Disconnect: LH Front Power Window Motor C524.
Are the resistances less than 3 ohms?
Yes MAKE SURE there are no mechanical binding conditions preventing the glass mechanism from operating correctly. If a mechanical binding issue is found, REPAIR as necessary. If no mechanical binding condition exists, INSTALL a new LH front window regulator motor. REFER to: Front Door Window Regulator Motor . No REPAIR the circuit in question.