Pinpoint Test C: No Power In On - Conventional Ignition Switch: Notes
Refer to Power Distribution/BCM for schematic and connector information.
Normal Operation and Fault Conditions
REFER to: Steering Wheel and Column Electrical Components - System Operation and Component Description
BCM DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| B1310:12 | Run/Start Control: Circuit Short to Battery | Sets when the BCM detects a short to voltage from the BJB run/start relay control circuit. When set, the control side of the run/start relay is disabled via the Field Effect Transistor (FET). Once the condition that caused the DTC to set is repaired, the BCM must pass a self-test in order for the DTC to clear and the system to resume normal operation. |
| B1310:14 | Run/Start Control: Circuit Short to Ground or Open | The BCM continuously monitors the control side of the RUN/START relay in the BJB. This DTC is set if the BCM detects an open or a short to ground on the control side of the RUN/START relay. When this DTC sets, the BCM disables the control side of the RUN/START relay FET. Once the condition that caused the DTC to set is repaired, the BCM must pass a self-test in order for the DTC to clear and the system to resume normal operation. |
| B1142:29 | Ignition Status 1: Signal Invalid | Sets when the BCM does not receive a valid ignition signal during a BCM self-test. |
Possible Causes
- Network concern
- Wiring, terminals or connectors
- Ignition switch
- BCM
- BJB
Visual Inspection and Diagnostic Pre-checks
- Inspect BCM fuse 4 (10A) and BJB fuse 62 (20A).