Home >> Ford >> 2022 >> Mustang Mach 1, Standard Trans >> Repair and Diagnosis >> Engine Mechanical >> Auxiliary Emission Control Systems >> Engine Emission Control - 5.0L 32V Ti-VCT (359KW/486PS) (WU)/5.0L Ti-VCT V8 (343KW/466PS) (MF) >> Removal And Installation >> Crankcase Ventilation Tube >> Removal

Crankcase Ventilation Tube: Removal

NOTE: Removal steps in this procedure may contain installation details.
  1. Disconnect the negative and positive battery cable. Refer to: Battery Disconnect and Connect .
  2. If equipped Remove and discard the nuts and remove the strut tower cross brace.

    Torque: 41 lb.ft (55 Nm)

    GFD717723Courtesy of FORD MOTOR COMPANY
  3. Remove the oil filling cap.
    GFD717913Courtesy of FORD MOTOR COMPANY
  4. Remove the engine appearance cover.
    GFD717914Courtesy of FORD MOTOR COMPANY
  5. NOTE: Inspect the o-rings and replace if necessary.

    Disconnect the crankcase ventilation tube-quick connect couplings and crankcase ventilation tube. Refer to: Quick Release Coupling .