Pinpoint Test Aa : P0A7A:96
- Normal Operation and Fault Conditions
REFER to: Electric Powertrain Control - System Operation and Component Description .
DTC Fault Trigger Conditions
DTC Description Fault Trigger Condition SOBDMC P0A7A:96 Generator Inverter Performance: Component Internal Failure This DTC sets when the module detects an internal hardware issue. Possible Sources
- Inverter System Controller (ISC)
- AA1 CHECK FOR INVERTER SYSTEM CONTROLLER (ISC) DIAGNOSTIC TROUBLE CODES (DTCS)
- Ignition ON.
- Using a diagnostic scan tool, perform the Inverter System Controller (ISC) self-test.
Are any Inverter System Controller (ISC) DTCs other than P0A7A:96 present?
Yes DIAGNOSE all other Inverter System Controller (ISC) DTCs, REFER to the Diagnostic Trouble Code (DTC) Chart . No For DTC P0A7A:96 only GO to AA2 - AA2 CLEAR AND READ THE INVERTER SYSTEM CONTROLLER (ISC) DIAGNOSTIC TROUBLE CODES (DTCS)
- Clear the Inverter System Controller (ISC) DTCs.
- Using a diagnostic scan tool, run the Inverter System Controller (ISC) self-test.
Is DTC P0A7A the only DTC read from the Inverter System Controller (ISC)?
Yes CHECK OASIS for any applicable service articles: TSB, GSB, SSM or FSA. If a service article exists for this concern, DISCONTINUE this test and FOLLOW the service article instructions. If no service articles address this concern, INSTALL a new Inverter System Controller (ISC). REFER to: Inverter System Controller [SOBDMC] . No The system is operating correctly at this time. The DTC may have been set due to high network traffic or an intermittent fault condition.