Pinpoint Test A : Transmission Control Solenoids
- Refer to Transmission Controls
for schematic and connector information.
Normal Operation and Fault Conditions
If the power circuit to the transmission solenoids fails open, then all solenoids are failed electrically off. Check for an open, short to ground or the transmission connector disconnected. The 10R60 utilizes 6 shift solenoids (A through F) that are linear force solenoids. Unlike previous shift solenoids they are mechanical in nature meaning no transmission fluid passes through them. CIDASs use an armature pin assembly that moves a control valve in the main control valve body to control and apply hydraulic fluid pressure. Each clutch (A through F) has a corresponding shift solenoid (A through F) that is directly proportional in that zero current equals zero pressure and maximum current equals maximum pressure. Since there is no pressure with zero current, none of the clutch packs are able to engage if the power is interrupted to the shift solenoids.
DTC Fault Trigger Conditions
DTC Description Fault Trigger Condition PCM P0657:00 Actuator Supply Voltage "A" Circuit/Open: No Sub Type Information This DTC sets if the PCM detects an open or short to ground in the TSPC circuitry. PCM P0753:00 Shift Solenoid "A" Electrical: No Sub Type Information This DTC sets if the fault was not present long enough for the PCM to determine more specific fault. If more specific DTCs such as P0973, P0974 or P097A are set resolve them first. PCM P0754:00 Shift Solenoid "A" Intermittent: No Sub Type Information This DTC sets if the fault was not present long enough for the PCM to determine more specific fault. If a more specific DTC is set resolve it first. PCM P0758:00 Shift Solenoid "B" Electrical: No Sub Type Information This DTC sets if the fault was not present long enough for the PCM to determine a more specific fault. If more specific DTC such as P0976, P0977 or P097B are set resolve them first. PCM P0759:00 Shift Solenoid "B" Intermittent: No Sub Type Information This DTC sets if the fault was not present long enough for the PCM to determine a more specific fault. If a more specific DTC is set resolve it first. PCM P0763:00 Shift Solenoid "C" Electrical: No Sub Type Information This DTC sets if the fault was not present long enough for the PCM to determine a more specific fault. If a more specific DTC such as P0979, P097C or P0980 are set resolve them first. PCM P0764:00 Shift Solenoid "C" Intermittent: No Sub Type Information This DTC sets if the fault was not present long enough for the PCM to determine a more specific fault. If a more specific DTC is set resolve it first. PCM P0768:00 Shift Solenoid "D" Electrical: No Sub Type Information This DTC sets if the fault was not present long enough for the PCM to determine a more specific fault. If a more specific DTC such as P097D, P0982 or P0983 are set resolve them first. PCM P0769:00 Shift Solenoid "D" Intermittent: No Sub Type Information This DTC sets if the fault was not present long enough for the PCM to determine a more specific fault. If a more specific DTC is set resolve it first. PCM P0773:00 Shift Solenoid "E" Electrical: No Sub Type Information This DTC sets if the fault was not present long enough for the PCM to determine a more specific fault. If a more specific DTCs such as P097E, P0985 or P0986 are set resolve them first. PCM P0774:00 Shift Solenoid "E" Intermittent: No Sub Type Information This DTC sets if the fault was not present long enough for the PCM to determine a more specific fault. If a more specific DTC is set resolve it first. PCM P0973:00 Shift Solenoid "A" Control Circuit Low: No Sub Type Information This DTC sets if the PCM detects a short to ground in the shift solenoid control circuitry. PCM P0974:00 Shift Solenoid "A" Control Circuit High: No Sub Type Information This DTC sets if the PCM detects a short to power in the shift solenoid control circuitry. PCM P0976:00 Shift Solenoid "B" Control Circuit Low: No Sub Type Information This DTC sets if the PCM detects a short to ground in the shift solenoid control circuitry. PCM P0977:00 Shift Solenoid "B" Control Circuit High: No Sub Type Information This DTC sets if the PCM detects a short to power in the shift solenoid control circuitry. PCM P0979:00 Shift Solenoid "C" Control Circuit Low: No Sub Type Information This DTC sets if the PCM detects a short to ground in the shift solenoid control circuitry. PCM P097A:00 Shift Solenoid "A" Control Circuit/Open: No Sub Type Information This DTC sets if the PCM detects an open in the shift solenoid control circuitry. PCM P097B:00 Shift Solenoid "B" Control Circuit/Open: No Sub Type Information This DTC sets if the PCM detects an open in the shift solenoid control circuitry. PCM P097C:00 Shift Solenoid "C" Control Circuit/Open: No Sub Type Information This DTC sets if the PCM detects an open in the shift solenoid control circuitry. PCM P097D:00 Shift Solenoid "D" Control Circuit/Open: No Sub Type Information This DTC sets if the PCM detects an open in the shift solenoid control circuitry. PCM P097E:00 Shift Solenoid "E" Control Circuit/Open: No Sub Type Information This DTC sets if the PCM detects an open in the shift solenoid control circuitry. PCM P097F:00 Shift Solenoid "F" Control Circuit/Open: No Sub Type Information This DTC sets if the PCM detects an open in the shift solenoid control circuitry. PCM P0980:00 Shift Solenoid "C" Control Circuit High: No Sub Type Information This DTC sets if the PCM detects a short to power in the shift solenoid control circuitry. PCM P0982:00 Shift Solenoid "D" Control Circuit Low: No Sub Type Information This DTC sets if the PCM detects a short to ground in the shift solenoid control circuitry. PCM P0983:00 Shift Solenoid "D" Control Circuit High: No Sub Type Information This DTC sets if the PCM detects a short to power in the shift solenoid control circuitry. PCM P0985:00 Shift Solenoid "E" Control Circuit Low: No Sub Type Information This DTC sets if the PCM detects a short to ground in the shift solenoid control circuitry. PCM P0986:00 Shift Solenoid "E" Control Circuit High: No Sub Type Information This DTC sets if the PCM detects a short to power in the shift solenoid control circuitry. PCM P0998:00 Shift Solenoid "F" Control Circuit Low: No Sub Type Information This DTC sets if the PCM detects a short to ground in the shift solenoid control circuitry. PCM P0999:00 Shift Solenoid "F" Control Circuit High: No Sub Type Information This DTC sets if the PCM detects a short to power in the shift solenoid control circuitry. PCM P2669:00 Actuator Supply Voltage "B" Circuit/Open: No Sub Type Information This DTC sets if the PCM detects an open in the TCC and LPC circuitry. PCM P2709:00 Shift Solenoid "F" Electrical: No Sub Type Information This DTC sets relationally if the DTCs P097F, P0998, P0999 are set, resolve these DTC first. PCM P2710:00 Shift Solenoid "F" Intermittent: No Sub Type Information This DTC sets if the fault was not present long enough for the PCM to determine a more specific fault. If a more specific DTC is set resolve it first. Possible Sources
- Connectors damaged or pushed-out terminals, corrosion, loose wires and missing or damaged seals
- Shift solenoid
- Clutch pack
- A1 CHECK THE SOLENOID POWER CIRCUIT FOR VOLTAGENOTE: Read and record all DTCs.
- Ignition OFF.
- Disconnect: Transmission Vehicle Harness C168A.
- Ignition ON.
- Measure:
Positive Lead Measurement / Action Negative Lead C168A-9 Ground
Is the voltage greater than 11 volts?
Yes GO to A4 No GO to A2 - A2 CHECK THE SOLENOID POWER CIRCUIT FOR AN OPEN
- Ignition OFF.
- Disconnect: PCM C175T
- Inspect the connector for damaged or pushed out terminals, corrosion, loose wires and missing or damaged seals.
Is the resistance less than 3 ohms?
Yes GO to A3 No REPAIR transmission vehicle harness circuit for an open. - A3 CHECK THE SOLENOID POWER CIRCUIT FOR A SHORT TO GROUND
- Measure:
Positive Lead Measurement / Action Negative Lead C175T-2 Ground
Is the resistance greater than 10, 000 ohms?
Yes Refer to PCM GUIDED ROUTINE TESTING
After programming the new PCM, CARRY OUT the transmission strategy download. REFER to: Transmission Strategy Download .No REPAIR the circuit. - Measure:
- A4 CHECK SOLENOID CONTROL CIRCUITS FOR AN OPEN
- Ignition OFF.
- Disconnect: PCM C175T
- Inspect the connector for damaged or pushed out terminals, corrosion, loose wires and missing or damaged seals.
- Measure the resistance of the solenoid control circuits using the following chart:
Positive Lead Measurement / Action Negative Lead SSA C175T-19 C168A-14 SSB C175T-49 C168A-15 SSC C175T-34 C168A-16 SSD C175T-64 C168A-21 SSE C175T-5 C168A-22 SSF C175T-4 C168A-23
Is the resistance less than 3 ohms on the suspect circuit?
Yes GO to A5 No REPAIR the transmission vehicle harness circuit. CLEAR the DTCs. - A5 CHECK SOLENOID CONTROL CIRCUITS FOR A SHORT TO GROUND
- Measure the resistance between the transmission vehicle harness C175T, harness side and ground using the following chart:
Positive Lead Measurement / Action Negative Lead SSA C175T-19 Ground SSB C175T-49 Ground SSC C175T-34 Ground SSD C175T-64 Ground SSE C175T-5 Ground SSF C175T-4 Ground
Is the resistance greater than 10, 000 ohms on the suspect circuit?
Yes GO to A6 No REPAIR the transmission vehicle harness circuit. CLEAR the DTCs. - Measure the resistance between the transmission vehicle harness C175T, harness side and ground using the following chart:
- A6 CHECK SOLENOID CONTROL CIRCUITS FOR A SHORT TOGETHER WITH VOLTAGE CIRCUITS
- Measure:
Positive Lead Measurement / Action Negative Lead C175T-19 C175T-35 C175T-19 C175T-50 C175T-19 C175T-1 C175T-19 C175T-39 C175T-19 C175T-42 C175T-19 C175T-17 C175T-19 C175T-36 C175T-19 C175T-55 C175T-19 C175T-2
- Measure:
Positive Lead Measurement / Action Negative Lead C175T-4 C175T-35 C175T-4 C175T-50 C175T-4 C175T-1 C175T-4 C175T-39 C175T-4 C175T-42 C175T-4 C175T-17 C175T-4 C175T-36 C175T-4 C175T-55 C175T-4 C175T-2
- Measure:
Positive Lead Measurement / Action Negative Lead C175T-34 C175T-35 C175T-34 C175T-50 C175T-34 C175T-1 C175T-34 C175T-39 C175T-34 C175T-42 C175T-34 C175T-17 C175T-34 C175T-36 C175T-34 C175T-55 C175T-34 C175T-2
- Measure:
Positive Lead Measurement / Action Negative Lead C175T-49 C175T-35 C175T-49 C175T-50 C175T-49 C175T-1 C175T-49 C175T-39 C175T-49 C175T-42 C175T-49 C175T-17 C175T-49 C175T-36 C175T-49 C175T-55 C175T-49 C175T-2
- Measure:
Positive Lead Measurement / Action Negative Lead C175T-5 C175T-35 C175T-5 C175T-50 C175T-5 C175T-1 C175T-5 C175T-39 C175T-5 C175T-42 C175T-5 C175T-17 C175T-5 C175T-36 C175T-5 C175T-55 C175T-5 C175T-2
- Measure:
Positive Lead Measurement / Action Negative Lead C175T-64 C175T-35 C175T-64 C175T-50 C175T-64 C175T-1 C175T-64 C175T-39 C175T-64 C175T-42 C175T-64 C175T-17 C175T-64 C175T-36 C175T-64 C175T-55 C175T-64 C175T-2
Are the resistances greater than 10, 000 ohms?
Yes GO to A7 No REPAIR the transmission vehicle harness circuit. CLEAR the DTCs. - Measure:
- A7 CHECK FOR SHORT TO TRANSMISSION FLUID PUMP VPWR CIRCUIT
- Ignition ON.
- Measure:
Positive Lead Measurement / Action Negative Lead SSA C175T-19 Ground SSB C175T-49 Ground SSC C175T-34 Ground SSD C175T-64 Ground SSE C175T-5 Ground SSF C175T-4 Ground
Is any voltage detected?
Yes REPAIR the circuit. No GO to A8 - A8 CHECK SOLENOID CONTROL CIRCUIT FOR AN OPEN CIRCUIT WITH TRANSMISSION HARNESS CONNECTED
- Ignition OFF.
- Connect Transmission Vehicle Harness C168A.
- REMOVE the transmission fluid pan. REFER to: Transmission Fluid Pan, Gasket and Filter .
- Disconnect All shift solenoid connectors.
- Measure, using the table below:
Positive Lead Measurement / Action Negative Lead SSA C175T-19 SSA C1843-2 SSB C175T-49 SSB C1844-2 SSC C175T-34 SSC C1845-2 SSD C175T-64 SSD C1846-2 SSE C175T-5 SSE C1847-2 SSF C175T-4 SSF C1848-2
Is the resistance less than 3 ohms on the suspect circuit?
Yes GO to A9 No INSTALL a new internal wiring harness. REFER to: Transmission Internal Wiring Harness . - A9 CHECK SOLENOID CONTROL CIRCUIT FOR A SHORT TO GROUND WITH TRANSMISSION HARNESS CONNECTED
- Measure, using the table below:
Positive Lead Measurement / Action Negative Lead SSA C175T-19 Ground SSB C175T-49 Ground SSC C175T-34 Ground SSD C175T-64 Ground SSE C175T-5 Ground SSF C175T-4 Ground
Is the resistance greater than 10, 000 ohms on the suspect circuit?
Yes GO to A10 No INSTALL a new internal wiring harness. REFER to: Transmission Internal Wiring Harness . - Measure, using the table below:
- A10 CHECK MAIN CONTROL WIRING HARNESS SOLENOID POWER CIRCUIT FOR VOLTAGE AT SOLENOIDS WITH TRANSMISSION HARNESS CONNECTED
- Connect PCM C175T.
- Ignition ON.
- Measure:
Positive Lead Measurement / Action Negative Lead SSA C1843-1 Ground SSB C1844-1 Ground SSC C1845-1 Ground SSD C1846-1 Ground SSE C1847-1 Ground SSF C1848-1 Ground
Is the voltage 11 volts or greater on the suspect circuit?
Yes INSTALL a new solenoid. REFER to: Shift Solenoids (SS) . No INSTALL a new internal wiring harness. REFER to: Transmission Internal Wiring Harness .