Pinpoint Test I : U300A:01

WARNING: This page is about a different car, the 2018 Ford EcoSport. However, it is still accessible from the selected car via links, so may be relevant.
  1. Refer to Power Distribution/BCM for schematic and connector information.

    Normal Operation and Fault Conditions 

    REFER to: Steering Wheel and Column Electrical Components - System Operation and Component Description .

    DTC Fault Trigger Conditions 

    DTC Description Fault Trigger Condition
    BCM U300A:01 Ignition Switch: General Electrical Failure Sets when the BCM detects an invalid combination from the ignition switch input circuits, such as a voltage signal only from the ON-designated circuit, a voltage signal only from the START-designated circuit or a voltage signal from ACC and START-designated circuits at the same time.

    Possible Sources 

    • Wiring, terminals or connectors
    • Ignition switch
    • BCM

  2. NOTE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
  3. I1 CHECK FOR IGNITION SWITCH CIRCUITS FOR A SHORT TO VOLTAGE

    • Ignition OFF.

    • Disconnect BCM C2280D.

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      Refer to C2280D-35
      GFD324697Courtesy of FORD MOTOR COMPANY
      Ground
      Refer to C2280D-34
      GFD324697Courtesy of FORD MOTOR COMPANY
      Ground
      Refer to C2280D-4
      GFD324697Courtesy of FORD MOTOR COMPANY
      Ground

    Is any voltage present? 

    Yes  REPAIR the circuit in question.
    No  GO to  I2
  4. I2 CHECK THE BCM (BODY CONTROL MODULE) IGNITION SWITCH INPUT CIRCUITS FOR VOLTAGE

    • Ignition ON.

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      Refer to C2280D-35
      GFD324697Courtesy of FORD MOTOR COMPANY
      Ground
      Refer to C2280D-34
      GFD324697Courtesy of FORD MOTOR COMPANY
      Ground

    • While placing the ignition switch to the START position, measure:
      Positive Lead Measurement / Action Negative Lead
      Refer to C2280D-34
      GFD324697Courtesy of FORD MOTOR COMPANY
      Ground
      Refer to C2280D-4
      GFD324697Courtesy of FORD MOTOR COMPANY
      Ground

    Are the voltages greater than 11 volts? 

    Yes  GO to  I4
    No  GO to  I3
  5. I3 CHECK THE IGNITION SWITCH CIRCUITS FOR AN OPEN

    • Ignition OFF.

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      Refer to C2280D-35
      GFD324698Courtesy of FORD MOTOR COMPANY
      Refer to C250-6
      Refer to C2280D-34
      GFD324698Courtesy of FORD MOTOR COMPANY
      Refer to C250-1
      Refer to C2280D-4
      GFD324698Courtesy of FORD MOTOR COMPANY
      Refer to C250-7

    Are the resistances less than 3 ohms? 

    Yes  INSTALL a new ignition switch. REFER to: Ignition Switch .
    No  REPAIR the circuit in question.
  6. I4 CHECK FOR CORRECT BCM (BODY CONTROL MODULE) OPERATION

    • Ignition OFF.

    • Disconnect and inspect all BCM connectors.

    • Repair:

      • corrosion (install new connector or terminals - clean module pins)
      • damaged or bent pins - install new terminals/pins
      • pushed-out pins - install new pins as necessary

    • Reconnect the BCM connectors and all other previously disconnected connectors. Make sure they seat and latch correctly.

    • Operate the system and determine if the concern is still present.

    Is the concern still present? 

    Yes  CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, INSTALL a new BCM. REFER to: Body Control Module (BCM) .
    No  The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.