Pinpoint Test Q : B10B5:11, B10B5:15
WARNING: This page is about a different car, the 2018 Ford EcoSport. However, it is still accessible from the selected car via links, so may be relevant.
- Automatic Climate Control System for schematic and connector information.
Normal Operation and Fault Conditions
Sensor inputs, center register air discharge temperature sensor, REFER to: Climate Control System - Vehicles With: Electronic Automatic Temperature Control (EATC) - System Operation and Component Description .
DTC Fault Trigger Conditions
DTC Description Fault Trigger Condition HVAC B10B5:11 Left Panel Air Discharge Temperature: Circuit Short To Ground This DTC sets when the HVAC module senses lower than expected voltage on the sensor feedback circuit, indicating a short to ground. HVAC B10B5:15 Left Panel Air Discharge Temperature: Circuit Short To Battery Or Open This DTC sets when the HVAC module senses greater than expected voltage on the sensor feedback circuit, indicating a short to voltage or an open circuit or sensor. Possible Sources
- Wiring, terminals or connectors
- Center register air discharge temperature sensor
- HVAC control module
Visual Inspection and Pre-checks
- Inspect loose or corroded HVAC control module and center register air discharge temperature sensor connections.
- NOTE: Use the correct probe adapter(s) when making measurements. Failure to. Use the correct probe adapter(s) may damage the connector.
- Q1 CHECK THE CENTER REGISTER AIR DISCHARGE TEMPERATURE SENSOR CIRCUITS FOR A SHORT TO VOLTAGE
- Ignition OFF.
- Disconnect HVAC control module C294A.
- Disconnect HVAC control module C294B.
- Disconnect Center register air discharge temperature sensor C2438.
- Ignition ON.
- Measure:
Positive Lead Measurement / Action Negative Lead Refer to C2438-1 Ground Refer to C2438-2 Ground
Is any voltage present?
Yes REPAIR the affected circuits. No GO to Q2 - Q2 CHECK THE CENTER REGISTER AIR DISCHARGE TEMPERATURE SENSOR CIRCUITS FOR A SHORT TO GROUND
- Ignition OFF.
- Measure:
Positive Lead Measurement / Action Negative Lead Refer to C2438-1 Ground Refer to C2438-2 Ground
Are the resistances greater than 10, 000 ohms?
Yes GO to Q3 No REPAIR the affected circuits. - Q3 CHECK THE CENTER REGISTER AIR DISCHARGE TEMPERATURE SENSOR CIRCUITS FOR AN OPEN
- Measure:
Positive Lead Measurement / Action Negative Lead Refer to C2438-1 Refer to C294B-5 Positive Lead Measurement / Action Negative Lead Refer to C2438-2 Refer to C294A-2
Are the resistances less than 3 ohms?
Yes GO to Q4 No REPAIR the affected circuits. - Measure:
- Q4 CHECK THE CENTER REGISTER AIR DISCHARGE TEMPERATURE SENSOR CIRCUITS FOR A SHORT TOGETHER
Is the resistance greater than 10, 000 ohms?
Yes GO to Q5 No REPAIR the circuits. - Q5 CHECK FOR CORRECT CENTER REGISTER AIR DISCHARGE TEMPERATURE SENSOR OPERATION
- Ignition OFF.
- Inspect the disconnected connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect all disconnected connectors. Make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes INSTALL a new center register air discharge temperature sensor. REFER to: Center Register Air Discharge Temperature Sensor . TEST the system for normal operation. If the concern is still present, GO to Q6 No The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. ADDRESS the root cause of any connector or pin issues. - Q6 CHECK FOR CORRECT HVAC (HEATING, VENTILATION AND AIR CONDITIONING) CONTROL MODULE OPERATION
- Ignition OFF.
- Disconnect and inspect all HVAC control module electrical connectors (if not previously disconnected).
- Repair:
- corrosion (install new connector or terminal - clean module pins)
- damaged or bent pins - install new terminals or pins
- pushed-out pins - install new pins as necessary
- Connect all HVAC control module electrical connectors. Make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK On-Line Automotive Service Information System (OASIS) for any applicable Technical Service Bulletins (TSBs). If a Technical Service Bulletin (TSB) exists for this concern, DISCONTINUE this test and FOLLOW Technical Service Bulletin (TSB) instructions. If no Technical Service Bulletins (TSBs) address this concern, INSTALL a new HVAC control module. REFER to: Heating, Ventilation and Air Conditioning (HVAC) Control Module . No The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. ADDRESS the root cause of any connector or pin issues.