LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2017 >> Escape S >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Information Center - Instrumentation, Message Center And Warning Chimes >> Description And Operation >> Instrument Panel Cluster (IPC) - System Operation and Component Description >> System Operation >> Auto Stop-Start Freeze Mode (1.5L Or 2.0L only)

Auto Stop-Start Freeze Mode (1.5L Or 2.0L only)

The IPC utilizes a stop-start freeze mode as directed by the PCM to freeze the current IPC state when the engine is restarted following a shut off. When the vehicle is in normal operation (not stop-start mode), the circuit remains high. When the PCM begins to crank the starter and restart the vehicle, ending the stop-start mode, the PCM pulls the stop-start input circuit low to the IPC. The IPC senses the low circuit and initiates the following actions: