Pinpoint Test K : B10D0:23, B1316:02, B1316:93: Notes
Refer to Wiring Diagrams Cell 109 for schematic and connector information.
Normal Operation and Fault Conditions
REFER to: Body Closures - System Operation and Component Description .
RGTM DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| B10D0:23 | Trunk Latch Clutch Switch: No Sub Type Information | Sets when sets when the RGTM detects a fault from the latch forkbolt input circuit. |
| B1316:02 | Boot/Trunk Latch Power Close Unit: General Signal Failure | Sets when sets when the RGTM detects a fault from the liftgate power striker motor when returning the motor to its rest position after the liftgate power striker motor has pulled the liftgate closed. |
| B1316:93 | Boot/Trunk Latch Power Close Unit: No Operation | Sets when sets when the RGTM detects a fault from the liftgate power striker motor during operation. |
Possible Causes
- Wiring, terminals or connectors
- Power liftgate latch
- Liftgate power striker motor
- RGTM
Visual Inspection and Diagnostic Pre-checks
- Inspect the liftgate latch for damage.