Pinpoint Test BA : U3006:16
- BA1 CARRY OUT THE IPC (INSTRUMENT PANEL CLUSTER) SELF-TEST
- Ignition ON.
- Using a diagnostic scan tool, clear the Diagnostic Trouble Codes (DTCs).
- Wait 10 seconds.
- Using a diagnostic scan tool, perform the IPC self-test.
Is DTC U3006:16 still present?
Yes GO to BA2 No The system is operating correctly at this time. The DTC may have been set due to a previous low battery voltage condition. - BA2 CHECK FOR CHARGING SYSTEM DIAGNOSTIC TROUBLE CODES (DTCS) IN THE BCM (BODY CONTROL MODULE)
- Using a diagnostic scan tool, perform the BCM on-demand self-test.
Are any charging system Diagnostic Trouble Codes (DTCs) recorded?
Yes REFER to: Body Control Module (BCM) No GO to BA3 - BA3 CHECK THE BATTERY CONDITION AND STATE OF CHARGE
- Check the battery condition and verify the battery is fully charged.
Is the battery OK and fully charged?
Yes GO to BA4 No CHARGE or INSTALL a new battery. REFER to: Battery - 1.6L EcoBoost (132kW/180PS) - Sigma REFER to: Battery - 2.5L Duratec (125kW/170PS) - BA4 CHECK THE IPC (INSTRUMENT PANEL CLUSTER) VOLTAGE SUPPLY AT THE IPC (INSTRUMENT PANEL CLUSTER)
- Ignition OFF.
- Disconnect IPC C220 .
- Ignition ON.
- Measure:
Positive Lead Measurement / Action Negative Lead C220-3 Ground
Is the voltage greater than 11 volts?
Yes GO to BA5 No REPAIR the circuit for high resistance. - BA5 CHECK THE IPC (INSTRUMENT PANEL CLUSTER) GROUND
Is the voltage greater than 11 volts?
Yes GO to BA6 No REPAIR the circuit for high resistance. - BA6 CHECK FOR CORRECT IPC (INSTRUMENT PANEL CLUSTER) OPERATION
- Ignition OFF.
- Disconnect and inspect the IPC connector.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect the IPC connector. Make sure it seats and latches correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, Refer to IPC Hardware Testing . No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.