Normal Operation
- DTC U3006:16 (Control Module Input Power "A": Circuit Voltage Below Threshold) - sets in the Instrument Panel Cluster (IPC) in continuous memory if the IPC detects battery voltage below 8 volts on the hot at all times B+ voltage supply circuit for more than one second after the engine has been running for longer than one second.
This pinpoint test is intended to diagnose the following:
- Wiring, terminals or connectors
- High circuit resistance
- IPC