LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2012 >> Mustang Base, 2D Coupe, Automatic Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 617 (Engine Controls - Powertrain DTC Charts & Descriptions (Except Diesel & Hybrid)) >> Diagnostic Trouble Code (DTC) Charts and Descriptions >> P2006 - Intake Manifold Runner Control (IMRC) Stuck Closed (Bank 1) - DTC Chart

P2006 - Intake Manifold Runner Control (IMRC) Stuck Closed (Bank 1) - DTC Chart

WARNING: This page does not describe the selected car, but rather 31 other vehicles, including the 2015 Lincoln Navigator, 2015 Lincoln MKZ, 2015 Lincoln MKX, 2015 Lincoln MKT, and 2015 Lincoln MKS. However, it is still accessible from the selected car via links, so may be relevant.
P2006 - INTAKE MANIFOLD RUNNER CONTROL (IMRC) STUCK CLOSED (BANK 1) - DTC CHART

Description:  This DTC sets when the IMRC is commanded open and the intake manifold runner control bank 1 (IMRC1) sensor indicates the IMRC is closed.
Possible Causes: 
  • IMRC circuit open
  • IMRC1 circuit open
  • IMRC1 circuit short to voltage
  • Damaged IMRC actuator
  • Damaged IMRC solenoid
Diagnostic Aids:  The IMRC1 sensor value should change when the IMRC is commanded open or closed.
Application  Key On Engine Off  Key On Engine Running  Continuous Memory 
All GO to Pinpoint Test HU .