Pinpoint Test At: U0214:00
- AT1 VERIFY THE CUSTOMER CONCERN
- Ignition ON.
- Verify there is an observable symptom present.
Is an observable symptom present?
- Yes: GO to AT2
- No: The system is operating normally at this time. The DTC may have been set due to high network traffic or an intermittent fault condition.
- AT2 CHECK THE COMMUNICATION NETWORK
- Ignition ON.
- Using a scan tool, perform the network test.
Does the RFA module pass the network test?
- Yes: GO to AT3
- No: REFER to: COMMUNICATIONS NETWORK .
- AT3 RETRIEVE THE RECORDED DIAGNOSTIC TROUBLE CODES (DTCS) FROM THE RFA (REMOTE FUNCTION ACTUATOR) MODULE SELF-TEST
- Using a scan tool, retrieve the continuous memory Diagnostic Trouble Codes (DTCs) from the RFA module.
Is DTC U3003:62 recorded?
- Yes: REFER to: REMOTE FUNCTION ACTUATOR (RFA) MODULE .
- No: GO to AT4
- AT4 RETRIEVE THE RECORDED DIAGNOSTIC TROUBLE CODES (DTCS) FROM THE IPC (INSTRUMENT PANEL CLUSTER) SELF-TEST
- Using a scan tool, perform the IPC self-test.
Are any DTC recorded?
- Yes:
For DTC U3006:16, GO to Pinpoint Test AM
For DTC U3006:17, GO to Pinpoint Test AN
- No: GO to AT5
- AT5 RECHECK THE IPC (INSTRUMENT PANEL CLUSTER) DIAGNOSTIC TROUBLE CODES (DTCS)
- Clear the Diagnostic Trouble Codes (DTCs).
- Wait 10 seconds.
- Repeat the IPC self-test.
Is DTC U0214:00 still present?
- Yes:
INSTALL a new RFA module.
REFER to: REMOTE FUNCTION ACTUATOR (RFA) MODULE .
CLEAR the Diagnostic Trouble Codes (DTCs). REPEAT the self-test.
If DTC U0214:00 is still present, INSTALL a new IPC.
REFER to: Instrument Panel Cluster (IPC) .
- No: The system is operating correctly at this time. The DTC may have been set due to high network traffic or an intermittent fault condition.