LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2000 >> Mustang Base, 2D Convertible, Automatic >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Instrument Panels - Analog >> System Tests >> Test U: Incorrect Tachometer Indication

Test U: Incorrect Tachometer Indication

Connect New Generation Star (NGS) tester to Data Link Connector (DLC). Turn ignition switch to RUN position. Using NGS tester, select instrument cluster active command TCHOMETER. Trigger, monitor and scroll TCHOMETER at 0%, 50% and 100%. Tachometer should indicate 0 RPM at 0%, middle RPM at 50% and maximum RPM at 100%. If tachometer responds as specified, repair engine speed input from PCM (retrieve codes from PCM). See appropriate SELF-DIAGNOSTICS article in ENGINE PERFORMANCE. If tachometer does not respond as specified, replace instrument cluster.