Hybrid Climate Control System Operation
When an A/C request is made by the HVAC module, a message is sent from the HVAC module over the Medium Speed Controller Area Network (MS-CAN) bus to the Instrument Cluster (IC), then from the IC through the High Speed Controller Area Network (HSCAN) bus to the PCM.
When an A/C request is received from the HVAC module, an A/C demand message is sent from the PCM over the HS-CAN bus to the ACCM if all of the following conditions are met:
- The PCM does not detect excessively high or low refrigerant pressure from the A/C pressure transducer.
- The PCM does not detect excessively high engine coolant temperature.
- The PCM does not detect an ambient air temperature below -1°C (30°F).
- The PCM has not detected a Wide Open Throttle (WOT) condition.
- The HVAC module does not detect an evaporator discharge air temperature below 2°C (36°F).
When the ACCM receives the A/C demand message, it will engage. Instead of cycling ON and OFF like a traditional A/C compressor, the ACCM monitors the evaporator discharge temperature to raise or lower the electric A/C compressor speed as required. When the HVAC module is OFF or not requiring A/C operation, the electric A/C compressor will be OFF.