Home >> Ford >> 2000 >> Contour SE, 2.5 L, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 1003 (Instrument Cluster System -- F150 Pickup) >> Diagnosis And Testing >> Instrument Cluster >> Pinpoint Test G: The Tachometer Is Inoperative >> Pinpoint Test G: The Tachometer Is Inoperative

Pinpoint Test G: The Tachometer Is Inoperative

WARNING: This page is about a different car, the 2005 Ford Pickup. However, it is still accessible from the selected car via links, so may be relevant.
  1. G1 RETRIEVE THE RECORDED POWERTRAIN CONTROL MODULE (PCM) DTCs FROM BOTH THE CONTINUOUS AND ON-DEMAND SELF-TESTS 
    • Check for the recorded PCM DTCs from the continuous and on-demand self-tests.
    • Are any PCM DTCs recorded? 
  2. G2 CARRY OUT THE INSTRUMENT CLUSTER TACHOMETER ACTIVE COMMAND USING THE DIAGNOSTIC TOOL 
    • Key in ON position.
    • Enter the following diagnostic mode on the diagnostic tool: Instrument Cluster Active Command.
    • Select the instrument cluster tachometer gauge active command. Trigger the active command on. Observe the tachometer gauge. The tachometer gauge should start 0 RPM and move to 700 RPM.
    • Is the tachometer gauge within specifications? 
    • Yes  : GO to  G3.
    • No  : GO to  G4.
  3. G3 CHECK FOR CORRECT PCM OPERATION 
    • Disconnect all the PCM connectors.
    • Check for:
      • Corrosion
      • Pushed-out pins
    • Connect all the PCM connectors and make sure they seat correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 
    • Yes  : INSTALL a new PCM. REFER to ELECTRONIC ENGINE CONTROLS . TEST the system for normal operation.
    • No  : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.
  4. G4 CHECK FOR CORRECT INSTRUMENT CLUSTER OPERATION 
    • Disconnect all the instrument cluster connectors.
    • Check for:
      • Corrosion
      • Pushed-out pins
    • Connect all the instrument cluster connectors and make sure they seat correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 
    • Yes  : INSTALL a new instrument cluster. REFER to INSTRUMENT CLUSTER . TEST the system for normal operation.
    • No  : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.