LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 1989 >> Taurus SHO >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Instrument Panel - Electronic >> Testing & Diagnosis >> Fuel Computer/System Scanner Module Self-Test >> Preliminary Information

Preliminary Information

Some vehicles may be equipped with a new graphics software for fuel computer/system scanner module. Display shown will depend on graphics package in vehicle. Both sets of graphics are shown. See FUEL COMPUTER/SYSTEM SCANNER MODULE SELF-TEST DISPLAYS illustration.

Enter self-test mode by holding "FUEL ECON" button in and turning ignition switch from "OFF" to "RUN". Advance through tests by pressing "FUEL ECON" button.

A tone and a "P" or "NORMAL" on display indicates test has passed. No tone and a "F" or "LIFTGATE AJAR" and "TAIL LAMP OUT" on display indicates test has failed. Test number is indicated in the tenths digit of fuel computer display. Exit test mode by completing last test or by turning ignition off.