Solenoid, WASTEGATE: Removal
- Disconnect and isolate the negative battery cable.
- Remove the air cleaner body. Refer to BODY, AIR CLEANER, REMOVAL .
- Disconnect the wastegate solenoid wire harness connector (1).
- Remove the vacuum hoses (2, 4, 5) from the wastegate solenoid (3).
- Remove the bolt (1) and the wastegate solenoid (3).