LEMON Manuals: Even more car manuals for everyone
Home >> Dodge and Ram >> 2003 >> Durango Base, 5.9 Z, RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 75 (HVAC - Plumbing) >> Refrigerant >> Diagnosis And Testing- Refrigerant System Leaks >> System Empty

System Empty

WARNING: This page is about a different car, the 2003 Dodge Dakota. However, it is still accessible from the selected car via links, so may be relevant.
  1. Evacuate the refrigerant system (Refer to REFRIGERANT - STANDARD PROCEDURE  ).
  2. Connect and dispense 0.283 kilograms (0.625 pounds or 10 ounces) of R-134a refrigerant into the evacuated refrigerant system (Refer to REFRIGERANT - STANDARD PROCEDURE  ).
  3. Position the vehicle in a wind-free work area. This will aid in detecting small leaks.
  4. With the engine not running, use a electronic R-134a leak detector and search for leaks. Because R-134a refrigerant is heavier than air, the leak detector probe should be moved slowly along the bottom side of all refrigerant lines, connector fittings and components.
  5. To inspect the evaporator coil for leaks, insert the electronic leak detector probe into the center instrument panel outlet and the floor duct outlet. Set the blower motor switch to the lowest speed position, and the mode control switch in the recirculation mode (Max-A/C).