LOW WASHER FLUID INDICATOR ALWAYS OFF - DIAGNOSTIC PROCEDURE
| TEST | ACTION |
|---|---|
| 1 | Turn the ignition off. Disconnect the Washer Fluid Level Switch connector. Check connectors - Clean/repair as necessary. Connect a jumper wire between the Washer Fluid Level Switch Sense circuit and the Washer Fluid Level Switch Ground circuit. Turn the ignition on.
NOTE:
The Instrument Cluster will delay illuminating the indicator for approximately 30 seconds. Observe the Low Washer Fluid Indicator. Does the indicator illuminate?
|
| 2 | Turn the ignition off. Disconnect the Washer Fluid Level Switch harness connector. Check connectors - Clean/repair as necessary. Using a 12-volt test light connected to 12-volts, check the Washer Fluid Level Switch Ground circuit. Does the test light illuminate brightly?
|
| 3 | Turn the ignition off. Disconnect the Instrument Panel C2 harness connector. Disconnect the Washer Fluid Level Switch harness connector. Check connectors - Clean/repair as necessary. Measure the resistance of the Washer Fluid Switch Sense circuit. Does the resistance measure above 5.0 ohms?
|