Diagnostic Procedure
WARNING: This page is about a different car, the 2004 Dodge Dakota. However, it is still accessible from the selected car via links, so may be relevant.
BLEND/MODE/RECIRC DOOR OPERATION IMPROPER - DIAGNOSTIC PROCEDURE
| TEST | ACTION |
|---|---|
| 1 |
NOTE:
All Actuator Circuit Test fault messages and Overcurrent DTCs must be repaired before diagnosing Calibration fault messages. Turn the ignition on.With the DRBIII(R) in HVAC, System Tests, actuate the Actuator Circuit Test.Does the DRBIII(R) display any Actuator Circuit Test fault messages?
|
| 2 |
NOTE:
All Actuator Circuit Test fault messages and Overcurrent DTCs must be repaired before diagnosing Calibration fault messages. Turn the ignition on.With the DRBIII(R), read active HVAC DTCs.Does the DRBIII(R) display any active HVAC DTCs?
|
| 3 |
NOTE:
All Actuator Circuit Test fault messages and Overcurrent DTCs must be repaired before diagnosing Calibration fault messages. Turn the ignition on.With the DRBIII(R) in HVAC, System Tests, actuate the HVAC Door Recalibration Test.Does the DRBIII(R) display any HVAC Door Recalibration fault messages?
|
| 4 | Which door did customer ID as faulty?
|
| 5 | Start the engine. Turn the blower control to the high speed position. Turn the mode select control to each door position for a minimum of 30 seconds and check for airflow from the corresponding vents. Does air flow from the correct vents for each door position?
|
| 6 | Start the engine. Turn the blower control to the high speed position. Turn the mode select control to the panel position. Turn the blend control to the full hot position. Turn the blend control to the full cold position, in 25% increments, while checking for a change in airflow air temperature coming from the panel vents. Does airflow air temp change at driver & pass panel vents with respect to position of blend control?
|
| 7 | Start the engine. Turn the blower control to the high speed position. Turn the mode select control to the panel position. Turn the mode select control to the MAX panel position. The sound of the air flowing through the ducts should get louder as the recirculation door opens to bring in recirc air. Does the sound of the airflow get louder after turning the control to the MAX panel position?
|