LEMON Manuals: Even more car manuals for everyone
Home >> Dodge and Ram >> 2003 >> Durango Base, 5.9 Z, RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 105 (Body Diagnostic Procedures) >> Diagnostic Information And Procedure >> Communication >> Symptom: *No Response From Overhead Console >> Diagnostic Procedure

Diagnostic Procedure

WARNING: This page is about a different car, the 2004 Dodge Dakota. However, it is still accessible from the selected car via links, so may be relevant.
NO RESPONSE FROM OVERHEAD CONSOLE - DIAGNOSTIC PROCEDURE

TEST ACTION
1
NOTE: Ensure there is PCI Bus communication with other modules on the vehicle before proceeding. If not, refer to the symptom list from the menu and repair as necessary.
Turn the ignition off.Disconnect the Overhead Console harness connector.Using a 12-volt test light connected to 12-volts, probe the ground circuit.Is the test light illuminated?
  1. Yes --> Go To 2
  2. No --> Repair the ground circuit for an open.

    Perform BODY VERIFICATION TEST - VER 1  .

2
NOTE: Ensure there is PCI Bus communication with other modules on the vehicle before proceeding. If not, refer to the symptom list from the menu and repair as necessary.
Turn the ignition off.Disconnect the Overhead Console harness connector.Turn the ignition on.Using a 12-volt test light connected to ground, probe the Fused Ignition Switch Output circuit.Is the test light illuminated?
  1. Yes --> Go To 3
  2. No --> Repair the Fused Ignition Switch Output circuit for an open.

    Perform BODY VERIFICATION TEST - VER 1  .

3
NOTE: Ensure there is PCI Bus communication with other modules on the vehicle before proceeding. If not, refer to the symptom list from the menu and repair as necessary.
Disconnect the Overhead Console harness connector.Use Scope input cable CH7058, Cable to Probe adapter CH7062, and the red and black test probes.Connect the scope input cable to the channel one connector on the DEB. Attach the red and black leads and the cable to probe adapter to the scope input cable.With the DRBIII(R) select Pep Module Tools.Select lab scope.Select Live Data.Select 12 volt square wave.Press F2 for Scope.Press F2 and use the down arrow to set voltage range to 20 volts. Press F2 again when complete.Connect the Black lead to the chassis ground. Connect the Red lead to the PCI Bus circuit in the Overhead Console connector.Turn the ignition on.Observe the voltage display on the DRB Lab Scope.Does the voltage pulse from 0 to approximately 7.5 volts?
  1. Yes --> Go To 4
  2. No --> Repair the PCI Bus circuit for an open.

    Perform BODY VERIFICATION TEST - VER 1  .

4 If there are no possible causes remaining, view repair.
  1. Repair
    1. Replace the Overhead Console in accordance with the service information.
    2. Perform BODY VERIFICATION TEST - VER 1  .