LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2011 >> 300 C, RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 602 (3.0L Diesel - DTCS P2009-00 To P2454-00 - 1500) >> Diagnosis And Testing >> P20F4-00-REDUCTANT Consumption Too Low >> Diagnostic Test

Diagnostic Test

WARNING: This page is about a different car, the 2014 RAM 1500. However, it is still accessible from the selected car via links, so may be relevant.
  1. ACTIVE DTC 
    NOTE:

    If there are any DEF Injector DTCs or DEF Supply/DEF Purge Pump DTCs present, perform the Diagnostics on those DTCs before continuing with this one.

    1. Turn the ignition on.
    2. With the scan tool, navigate to the DEF Injector Quantity Test.
    3. With the scan tool, View DTCs.

      Is the DTC active?

      Yes 

      • Go To  2

      No 

  2. CHECK THE DEF TANK LEVEL AND FLUID 
    1. Verify the DEF Tank level.
    2. Check the fluid for signs of contamination.

      Is the fluid level in the DEF Tank above the minimum requirement and free of contamination?

      Yes 

      • Go To  3

      No 

      • Fill the DEF Tank to the proper level with clean Diesel Exhaust Fluid. If the fluid is contaminated, perform the cleaning procedure.
      • Perform the POWERTRAIN VERIFICATION TEST. Refer to PCM VERIFICATION TEST .
  3. CHECK THE DEF SUPPLY SYSTEM FOR LEAKS 
    1. Using the scan tool, begin the DEF Injector Quantity Test
    2. During the DEF Injector Quantity Test, visually inspect the DEF Supply Pump Assembly and DEF Pressure Line for signs of a fluid leak.

      Are there any leaks in the DEF System?

      Yes 

      • Perform the appropriate repair.
      • Perform the POWERTRAIN VERIFICATION TEST. Refer to PCM VERIFICATION TEST .

      No 

      • Go To  4
  4. CHECK THE DEF INJECTOR 
    1. Stop actuation of the DEF Injector Quantity Test.
    2. Turn the ignition off.
    3. Remove the DEF Injector and place in a clean container.
    4. Turn the ignition on.
    5. With the scan tool, navigate to Systems Tests and actuate the DEF Injector Quantity Test.
      NOTE:

      When the DEF Injector (Dosing Valve) Actuator Test is initiated, the DEF Injector is opened. Wait 30 seconds before checking for leaks.

    6. Check the DEF Injector for a leak.

      Is the DEF Injector leaking?

      Yes 

      No 

      • Replace the DEF Supply Pump Assembly in accordance with the service information.
      • Perform the POWERTRAIN VERIFICATION TEST. Refer to PCM VERIFICATION TEST .