Diagnostic Test
WARNING: This page is about a different car, the 2013 RAM 3500 HD and 2013 RAM 2500 HD. However, it is still accessible from the selected car via links, so may be relevant.
- ACTIVE DTC
- Turn the ignition on, engine not running.
- With the scan tool, navigate to Systems Tests and actuate the Diesel Exhaust Fluid Doser Pump Override Test.
- With the scan tool, View DTCs.
Is the DTC Active?
Yes
- Go To 2
No
- Perform the INTERMITTENT CONDITION - 6.7L diagnostic procedure. Refer to STANDARD PROCEDURE .
- CHECK THE DEF SUPPLY PUMP MOTOR A SUPPLY CIRCUIT FOR A SHORT TO GROUND
- Turn the ignition off.
- Disconnect the DEF Supply Pump Assembly harness connector.
- Disconnect the DEF Dosing Control Unit C2 harness connector.
- Measure the resistance between ground and the DEF Supply Pump Motor A Supply circuit at the DEF Supply Pump Assembly harness connector.
Is the resistance above 10k Ohms?
Yes
- Go To 3
No
- Repair the DEF Supply Pump Motor A Supply circuit for a short to ground.
- Perform the POWERTRAIN VERIFICATION TEST - 6.7L. Refer to STANDARD PROCEDURE .
- CHECK THE DEF SUPPLY PUMP MOTOR B SUPPLY CIRCUIT FOR A SHORT TO GROUND
- Measure the resistance between ground and the DEF Supply Pump Motor B Supply circuit at the DEF Supply Pump Assembly harness connector.
Is the resistance above 10k Ohms?
Yes
- Go To 4
No
- Repair the DEF Supply Pump Motor B Supply circuit for a short to ground.
- Perform the POWERTRAIN VERIFICATION TEST - 6.7L. Refer to STANDARD PROCEDURE .
- Measure the resistance between ground and the DEF Supply Pump Motor B Supply circuit at the DEF Supply Pump Assembly harness connector.
- CHECK THE DEF SUPPLY PUMP MOTOR C SUPPLY CIRCUIT FOR A SHORT TO GROUND
- Measure the resistance between ground and the DEF Supply Pump Motor C Supply circuit at the DEF Supply Pump Assembly harness connector.
Is the resistance above 10k Ohms?
Yes
- Go To 5
No
- Repair the DEF Supply Pump Motor C Supply circuit for a short to ground.
- Perform the POWERTRAIN VERIFICATION TEST - 6.7L. Refer to STANDARD PROCEDURE .
- Measure the resistance between ground and the DEF Supply Pump Motor C Supply circuit at the DEF Supply Pump Assembly harness connector.
- CHECK THE DEF DOSING CONTROL UNIT
- Reconnect the DEF Dosing Control Unit C2 harness connector.
- Turn the ignition on.
- With a scan tool, View DTCs.
Did DTC P208A become active and DTC P208C change to stored?
Yes
- Replace the DEF Supply Pump Assembly in accordance with the service information. Refer to ASSEMBLY, DIESEL EXHAUST FLUID PUMP, REMOVAL .
- Perform the POWERTRAIN VERIFICATION TEST - 6.7L. Refer to STANDARD PROCEDURE .
No
- Replace the DEF Dosing Control Unit in accordance with the service information. Refer to UNIT, DIESEL EXHAUST FLUID DOSING CONTROL, REMOVAL .
- Perform the POWERTRAIN VERIFICATION TEST - 6.7L. Refer to STANDARD PROCEDURE .