Diagnostic Test
WARNING: This page is about a different car, the 2012 RAM Cab & Chassis. However, it is still accessible from the selected car via links, so may be relevant.
- ACTIVE DTC
- Turn the ignition on, engine not running.
- With the scan tool, navigate to Actuator Tests and actuate the DEF Supply Pump Heater.
- With the scan tool, View DTCs.
Is the DTC Active?
Yes
- Go To 2.
No
- Perform the INTERMITTENT CONDITION diagnostic procedure. Refer to INTERMITTENT CONDITION - 6.7L .
- CHECK THE RESISTANCE OF THE DEF SUPPLY PUMP HEATER
- Turn the ignition off.
- Disconnect the DEF Supply Pump Assembly harness connector.
- Measure the resistance across the terminals of the DEF Supply Pump Heater circuits at the DEF Supply Pump Assembly.
Is the resistance above 2.0 Ohms?
Yes
- Go To 3.
No
- Replace the DEF Supply Pump Assembly in accordance with the service information. Refer to ASSEMBLY, DIESEL EXHAUST FLUID PUMP, REMOVAL .
- Perform the POWERTRAIN VERIFICATION TEST. Refer to POWERTRAIN VERIFICATION TEST - 6.7L .
- CHECK THE (K472) DEF SUPPLY PUMP HEATER RETURN CIRCUIT FOR A SHORT TO GROUND
Courtesy of CHRYSLER GROUP, LLC
- Disconnect the DEF Dosing Control Unit C1 harness connector.
- Measure the resistance between ground and the (K472) DEF Supply Pump Heater Return circuit at the DEF Supply Pump Assembly harness connector.
Is the resistance above 10k Ohms?
Yes
- Go To 4.
No
- Repair the (K472) DEF Supply Pump Heater Return circuit for a short to ground.
- Perform the POWERTRAIN VERIFICATION TEST. Refer to POWERTRAIN VERIFICATION TEST - 6.7L .
- CHECK THE (K471) DEF SUPPLY PUMP HEATER SUPPLY CIRCUIT FOR A SHORT TO GROUND
Courtesy of CHRYSLER GROUP, LLC
- Disconnect the DEF Dosing Control Unit C1 harness connector.
- Measure the resistance between ground and the (K471) DEF Supply Pump Heater Supply circuit at the DEF Supply Pump Assembly harness connector.
Is the resistance above 10k Ohms?
Yes
- Replace the DEF Dosing Control Unit in accordance with the service information. Refer to UNIT, DIESEL EXHAUST FLUID DOSING CONTROL, REMOVAL .
- Perform the POWERTRAIN VERIFICATION TEST. Refer to POWERTRAIN VERIFICATION TEST - 6.7L .
No
- Repair the (K471) DEF Supply Pump Heater Supply circuit for a short to ground.
- Perform the POWERTRAIN VERIFICATION TEST. Refer to POWERTRAIN VERIFICATION TEST - 6.7L .