TUBE, Heater Hose, Supply: Removal: 3.5L
| 1 - COOLANT TEMPERATURE SENSOR |
| 2 - O-RING |
| 3 - BOLT |
| 4 - HEATER SUPPLY TUBE |
| 5 - BOLT |
- Drain cooling system. See Cooling - Standard Procedure .
- Remove upper and lower intake manifold. Refer to UPPER INTAKE MANIFOLD and LOWER INTAKE MANIFOLD .
- Position lower intake manifold upside down on bench and remove the tube retaining bolt (5).
- Remove heater supply tube (4) from manifold and discard O-ring (2).