Cable-Mode Door: Installation
NOTE:
Illustration shown with instrument panel removed for clarity.
- Position the mode control cable (4) to the right side of the HVAC air distribution housing (3).
- Connect the mode control cable to the mode door lever (2).
- Install the screw (1) that secures the mode control cable to the air distribution housing. Tighten the screw to 2 N.m (17 in. lbs.).
NOTE: Illustration shown with instrument panel removed for clarity.
- Engage the top of the mode door linkage cover (4) to the right side of the air distribution housing (1).
- Install the screw (3) that secures the mode door linkage cover and the right floor distribution duct (2) to the air distribution housing. Tighten the screw to 2 N.m (17 in. lbs.).
- Reach through the glove box opening and engage the two retainers (4) that secure the instrument panel wire harness (5) to the instrument panel support (1).
- Position the glove box damper (3) to the instrument panel support and install the two retaining screws (2). Tighten the screws to 2 N.m (17 in. lbs.).
- Install the glove box, (Refer to BODY/INSTRUMENT PANEL/BIN-GLOVE BOX - INSTALLATION) .
- Install the passenger side instrument panel silencer, (Refer to BODY/INSTRUMENT PANEL/SILENCER-INSTRUMENT PANEL - INSTALLATION) .
- Connect the mode door control cable to the A/C-heater control and install the instrument panel center bezel, (Refer to BODY/INSTRUMENT PANEL/BEZEL-CENTER - INSTALLATION) .
- Reconnect the negative battery cable.