If the system has lost all charge due to a leak:

  1. Evacuate the system. (Refer to PRESSURE SWITCH CHECK  .)
  2. Charge the system with approximately 0.453 kg (1 pound) of refrigerant.
  3. Check for leaks.
  4. Discharge the system.
  5. Repair leaks.
    CAUTION: Replacement filter-drier units must be sealed while in storage. The drier used in these units will saturate water quickly upon exposure to the atmosphere. When installing a drier, have all tools and supplies ready for quick assembly to avoid keeping the system open any longer than necessary.
  6. Replace receiver drier.
  7. Evacuate and charge system.