LEMON Manuals: Even more car manuals for everyone
Home >> Chrysler >> 2001 >> Sebring LX, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 27 (Mechanical Brake System - Base (Service Information) - Coupe) >> On-Vehicle Service >> Proportioning Valve Function Test

Proportioning Valve Function Test

WARNING: This page is about a different car, the 2005 Dodge Stratus and 2005 Chrysler Sebring. However, it is still accessible from the selected car via links, so may be relevant.
  1. Connect two pressure gauges, one each to the input side and output side of the proportioning valve, as shown.
  2. Air bleed the brake line and the pressure gauge.
  3. While gradually depressing the brake pedal, make the following measurements and check to be sure that the measured values are within the allowable range.
    1. Output fluid pressure begins to drop relative to input fluid pressure (split point).

      Standard value: 2.7 - 3.2 MPa (391 - 462 psi) 

    2. Check that the output fluid pressure is at standard value when the input fluid pressure indicates 9.8 MPa (1,422 psi).

      Standard value: 4.3 - 5.1 MPa (619 - 732 psi) 

    3. Output fluid pressure difference between left and right brake lines.

      Limit: 0.4 MPa (57 psi) 

  4. If the measured fluid pressures are not within allowable ranges, replace the proportioning valve.
    Fig 1: Connecting Pressure Gauges
    G04537075Courtesy of DAIMLERCHRYSLER CORPORATION
    Fig 2: Input Fluid Pressure Graph
    G04537076Courtesy of DAIMLERCHRYSLER CORPORATION