Installation Procedure
- Install the brake pressure modulator valve pipe assembly.
- CAUTION:
Brake Pressure Modulator Valve Primary Pipe Fitting (1) - Install and tighten 32 N.m (24 lb ft)
Brake Pressure Modulator Valve Secondary Pipe Fitting (1) - Install and tighten 32 N.m (24 lb ft)
Master Cylinder Primary Brake Pipe Fitting (1) - Install and tighten 32 N.m (24 lb ft)
Master Cylinder Secondary Brake Pipe Fitting (1) - Install and tighten 32 N.m (24 lb ft)
Clip (1) - Secure
Clip (1) - Secure
- Radiator Surge Tank Replacement (LTG) , or Radiator Surge Tank Replacement (LFV) - Install
- Bleed the brake system. Hydraulic Brake System Bleeding (Pressure) , or Hydraulic Brake System Bleeding (Manual)