LEMON Manuals: Even more car manuals for everyone
Home >> Chevrolet >> 2019 >> Cruze Premier, 4D Hatchback >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 1 (Engine Controls And Fuel - 1.6L (LH7) Diesel - Repair Instructions) >> Repair Instructions >> Emission Reduction Fluid Tank Replacement (Notchback) >> Installation Procedure

Installation Procedure

WARNING: This page is about a different variant/trim than selected.
  1. GM4297876Courtesy of GENERAL MOTORS COMPANY

    Emission Reduction Fluid Tank (2) - Install

  2. Support the emission reduction fluid tank (1) with a suitable jack.
  3. Emission Reduction Fluid Tank Nut (1) - Install and tighten [2x] 22 N.m (16 lb ft)
  4. Emission Reduction Fluid Tank Bolt (3) - Install and tighten [3x] 22 N.m (16 lb ft)
  5. GM4297867Courtesy of GENERAL MOTORS COMPANY

    Emission Reduction Fluid Tank Shield (1) - Install

  6. Clip (2) - Install [3x]
  7. Fig 1: Identifying Emission Reduction Fluid Controller And Components
    GM4297866Courtesy of GENERAL MOTORS COMPANY

    Emission Reduction Fluid Exhaust Front Pipe Injector Supply Pipe (1) @ Clip (6, 7) - Install [2x]

  8. Remove the tightness tool from the emission reduction fluid exhaust front pipe injector supply pipe (1).
  9. Emission Reduction Fluid Exhaust Front Pipe Injector Supply Pipe (1) - Connect
  10. Wiring Harness (3) @ Clip (4) - Install
  11. Connect the electrical connector:
    1. Emission Reduction Fluid Controller (5)
    2. Emission Reduction Fluid Exhaust Front Pipe Injector Supply Pipe Electrical Connector (2)
  12. GM4297865Courtesy of GENERAL MOTORS COMPANY

    Install the emission reduction fluid shield door (1).

  13. Clip (2) - Install
  14. GM4297875Courtesy of GENERAL MOTORS COMPANY

    Connect the 2 emission reduction opening filler quick connectors (2) to the emission reduction fluid tank (1). Plastic Collar Quick Connect Fitting Service 

  15. Rear Wheelhouse Liner-Right Side - Install - Rear Wheelhouse Liner Replacement
  16. Lower the vehicle.
  17. NOTE:

    The drained emission reduction fluid should not be re-used.

  18. Refill the emission reduction fluid tank with NEW emission reduction fluid with a minimum of 5 liters (5.28 quarts).
  19. When the replacement is completed, use a scan tool to perform the appropriate reset functions. Reductant Fluid Tank Level Reset 
  20. If replacing, reprogram the module. Control Module References