Home >> Chevrolet >> 2018 >> Spark LT, Automatic CVT Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 59 (Engine Mechanical - 1.4L (LV7) - Repair Instructions - On Vehicle) >> Repair Instructions - On Vehicle >> Positive Crankcase Ventilation Valve Replacement (L5Q (Rear)) >> Installation Procedure

Installation Procedure

WARNING: This page is about a different car, the 2017 Chevrolet Spark. However, it is still accessible from the selected car via links, so may be relevant.
  1. Assemble the New positive crankcase ventilation valves (3) with the air cleaner outlet duct (1) and New positive crankcase ventilation tube (2).
    Fig 1: Positive Crankcase Ventilation (PCV) Tube Assembly Components
    GM4234882Courtesy of GENERAL MOTORS COMPANY
  2. Install the air cleaner outlet duct assembly (1, 2, 3) with positive crankcase ventilation tube and valve to the engine.
    Fig 2: Positive Crankcase Ventilation (PCV) Tube Assembly Components
    GM4234866Courtesy of GENERAL MOTORS COMPANY
  3. Using EN-50956  tamper proof drive bit tighten bolts (4) to 10 N.m (89 lb in).
  4. Position the air cleaner outlet duct (1) in place and tighten the clamp (2) on the engine.
    Fig 3: Air Cleaner Outlet Duct And Clamp
    GM4234858Courtesy of GENERAL MOTORS COMPANY
  5. Install the positive crankcase ventilation tube (front). Refer to Positive Crankcase Ventilation Tube Replacement (L5Q (Front)) Positive Crankcase Ventilation Tube Replacement (L5Q (Rear)) .