Removal Procedure
WARNING: This page is about a different variant/trim than selected.
- Remove Intake Manifold Cover Replacement .
- Disconnect Positive Crankcase Ventilation Tube @ Air Cleaner Outlet Duct - Air Cleaner Outlet Duct Replacement (Non-Tamperproof)Air Cleaner Outlet Duct Replacement (Tamperproof)
- Using a suitable cutting tool, cut a slot in the fasteners. Remove the PCV valve fasteners with a flat blade screw driver and DISCARD (1).
- Remove the PCV hose fastener (2) from the camshaft cover.
- Remove the PCV valves and PCV tube assembly.
NOTE:
PCV Valve fasteners are tamper proof and must have a slot cut in the fastener to be removed.
NOTE:
PCV valves and PCV tube assembly have tamper-proof connections and cannot be disassembled.