Component Testing
WARNING: This page is about a different variant/trim than selected.
- Test the B193B Charge Air Cooler Temperature sensor by varying the sensor temperature while monitoring the air temperature with a thermometer. Compare the readings with the scan tool CAC Temperature Sensor parameter. The values should be within 5%.
- If not within the specified range, replace the B193B Charge Air Cooler Outlet Temperature sensor.