Circuit/System Description
The selective catalytic reduction system reduces oxides of nitrogen (NOx) emissions by injecting a metered amount of reductant into the exhaust gas stream entering the selective catalytic reduction catalyst. Within the selective catalytic reduction catalyst, the reductant reacts with the NOx to form nitrogen, carbon dioxide, and water vapor. Upstream and downstream NOx sensors provides the engine control module and the reductant control module via serial data. The engine control module (ECM) controls the reductant injector duty cycle in response to changes in engine-out NOx levels. The reductant control module supplies system voltage to the reductant pump motor. The reductant control module controls the solenoid by grounding the control circuit. The reductant control module can determine if the control circuit is open, shorted to ground, or shorted to a voltage by monitoring the feedback voltage.