Diagnostic Aids
WARNING: This page is about a different variant/trim than selected.
- A disconnected Camshaft Position Sensor could set DTC P0606 and may cause a no crank condition.
- Low voltage or a momentary loss of power or ground to the ECM may cause a DTC to set. Verify the following:
- The battery cables are clean and tight, and the battery is fully charged. Refer to Battery Inspection/Test .
- The ECM ground circuits do not have an open or high resistance.
- The ECM power circuits do not have an open, short to ground or high resistance.