Battery Sulfation Mode
WARNING: This page is about a different variant/trim than selected.
The BCM will enter this mode when the interpreted charging system voltage is less than 13.2 V for 30 minutes. When this condition exists the BCM will enter Normal Mode for 5 minutes. The BCM will then determine which mode to enter depending on voltage requirements.