Diagnostic Aids
WARNING: This page is about a different variant/trim than selected.
A short to ground or short to voltage on one reference voltage circuit can affect all the components connected to the same reference supply.
- The 5V reference 1 circuit is not used on this application.
- The 5V reference 2 circuit provides 5V reference to the B1C A/C Low Side Pressure Sensor.
- The 5V reference 3 circuit provides 5V reference to the internal high voltage measuring and isolation detection circuits.
- The 5V reference 4 circuit provides 5V reference to the B30 Hybrid/EV Battery Pack Current Sensor.
- The 5V reference 5 circuit provides 12V reference to the circuits listed below:
- G35 Hybrid/EV Electronics Coolant Pump, enable, feedback and control circuits
- Pre-Charge, Main positive and Main Negative high voltage contactor relay PWM control circuits
- G14 Hybrid/EV Battery Pack Cooling Fan, enable, feedback and control circuits
- Hood Switch