Circuit/System Verification
- Ignition ON, verify fuel level segments illuminate during Engineering Mode. Refer to Engineering Mode Description and Operation .
- If the fuel level segments do not illuminate
Replace the P16 Instrument Cluster.
- Go to next step: If the fuel level segments illuminate
- If the fuel level segments do not illuminate
- Observe the scan tool Instrument Cluster Fuel Level Sensor parameter. The reading should be 0.5 - 14.0 gal and vary with fuel level.
- If the reading does not vary with fuel level
Refer to Circuit/System Testing in the following below.
- Go to next step: If the reading varies with fuel level
- If the reading does not vary with fuel level
- All OK.